Skip to main content

NXG-508N

xGenConnect 8 relay output expander
  • 8 relay output expander for xGenConnect
  • Single Pole Double Throw (SPDT) Form C relays
  • 3 selectable operating modes for each output
  • Status LED for each output
  • Seperate box tamper input
View all

At a glance

Increasing output capability

The NXG-508N adds 8 additional relay outputs to the GenConnect range of panels. Via a jumper, each Single Pole Double Throw (SPDT) Form C relay output can be configured in 3 different modes: as dry contact, or to switch the bus or externally supplied voltage to the output terminal, or to switch the bus ground to the output terminal. This allows to use the module in different applications. The status LED next to each output shows the actual state of the relay.

Installation

The module comes with a set of card slides allowing the module to be slided into the xGenConnect control panel enclosure.

Programming

Enrolling the module and programming the outputs is done from the control panel. The firmware of the module is upgradeable remotely via DLX900 or locally using the USB flash device.

Details

  • 8 relay output expander for xGenConnect
  • Single Pole Double Throw (SPDT) Form C relays
  • 3 selectable operating modes for each output
  • Status LED for each output
  • Seperate box tamper input
  • "NetworX" form factor
  • Firmware upgrade via USBUP-EUR flash tool or via DLX900 over the network
  • EN50131-3 CLASS II GRADE 2, INCERT T031, NFA2P

Technical specifications

System
Product line
xGenConnect
Kit
No
Outputs
No. of outputs
8 SPDT relays
Rated load 0.5 A, 30 VAC or 1 A, 24 VDC
Minimum load 1 mA, 5 VDC
Maximum load 1 A, 24 VDC
Communication
Databus type
RS485
Electrical
Operating voltage
12 to 13.5 VDC (provided by panel)
Current consumption
130 mA (maximum, all outputs active)
20 mA (minimum, no outputs active)
Physical
Physical dimensions
153 x 57 mm
Shipping weight
70 g
Environmental
Operating temperature
0 to +49°C
Storage temperature
-34 to 60°C
Relative humidity
85% noncondensing
Regulatory
EN50131 Grade
Grade 2
Compliancy
CE
Certification
EN50131 Grade 2
INCERT
NFA2P
Inputs
Tamper input Normally closed